Waterproofing Membrane And Its 2 Types And Its Procedure

1. What is Waterproofing Membrane
It is a thin layer of watertight material which is laid over the surface to prevent leaking. The waterproofing membrane is a continuous layer and doesn’t allow water to pass through it. This membrane is mostly installed over the structural slab on a flat terrace and below the finish tiles.
Waterproofing membranes are composed of a thin layer of watertight material. Mostly these bitumen membranes are 3 mm or 4 mm thick. These sheets are used to prevent the water from penetrating inside the buildings. It is usually applying to a building at the time of construction. The main purpose of these sheets to control the seepage and moisture.

2. Where Are The Waterproof Membrane Used?
Waterproofing membranes are mostly used in the different parts of the building structures which includes,
Waterproofing of Terrace floors
Waterproofing of Roofs and slabs underground water tanks
Bathrooms waterproofing
Water carriage system WC waterproofing
Swimming pools waterproofing
Underground ducts, basements waterproofing
Waterproofing in gutters
Waterproofing over the balconies
Waterproofing in concrete water tanks
Waterproofing over concrete decks.
These membranes include both the positive and negative sides. The positive side membranes are installed to the face of the element which directly avoids the moisture to the exterior surface. Negative side membranes are installed to the surface of the element to avoid the moisture opposite to the surface.
It should be strong, flexible and elastic, which can stretch to cover the cracks. If you are applying membrane sheets is to be exposed to the sun so the sheet should be ultraviolet first.

These sheets have arrived at the site in the form of rolls. Then these sheets are unrolled and laid on a surface. Bituminous sheets are the most common type of membrane.

3. Properties Of Waterproofing Membrane
In the membrane installation work, we have to provide an overlap of 4 inches or 100 mm to form a waterproof joint. Sometimes we use an air gas gun to melt a sheet and then overlapped them on the previously membrane sheet laid early. These sheets have the ability to stretch and can be stretch 1.5 times its original length.

The sheets elongation or flexibility properties allows the membrane to stretch over the cracks. The membrane has the ability to withstand the tear and wear. You took a sample of membrane material in your hand and trying to tear the sample into two pieces. This gives us a fair idea about the sheets tear resistance.

If the membrane is to places in a complicated shape like in beam-column junction, then you must be applied liquid on it. In the sheet membrane, you should leave the gaps between the underlay and membrane sheet.

4. Membranes Can Be Classified Into Two Types,


Sheet-based waterproofing membrane and 

Liquid-based waterproofing membrane

4.1: Sheet Based Membrane
These sheets are available in the form of rolls. Before it uses, it should be unrolled and laid on the firm surface. Bituminous sheets are the most common type of membrane sheets are used.
Bituminous waterproofing membranes sheets are stuck to the substrate with the hot tar using the blowtorches based on adhesive. These sheets are 2 to 4mm thick. These membranes can be cut into the desired shape and size to the surface area required of the roof.
Optional materials are SINOMACO APP3mm or 4mm bitumen membrane, or SBS membrane.

4.2: Liquid Applying Waterproofing Membrane
These membranes have come to the site in the form of liquid and then it can be sprayed or brushed on to the surface area. This type is totally different from the sheet type membranes in which no overlap, weld or steam is required.
When spraying liquid forms of the monolithic membrane should be used. The thickness of these membranes is not fixed, it can be controlled as per your desired requirement. This layer is easily broken.
The liquid-based membrane process is quick and finished in one day easily. For the large areas, it can take several days. These membranes have a property to stick to itself.waterproofing liquid
Optional Materials are SINOMACO SA2000 acrylic based coating, S2000 Silicone based liquid membrane or SPU1000 polyurethane liquid membrane, they all can be applied by brushing or air spraying.

5. Sampled Procedure Of Waterproofing By Liquid Membrane

5.1: Waterproofing Of Sloping Terrace:
Clean all the surface area of the sloping terrace, and then applying a thick cement slurry over the surface of the terrace. You should be applying the SINOMACO SC2000 cementitious coating or SPU1000 polyurethane coating as liquid waterproofing membrane.

This liquid membrane can be cured after 24 hours then apply a second layer as your design demand.
Applying a cement sand mortar of ratio 1:4 over the finishing coat and waterproofing material as per design. Edge is provided between the parapet and the sloping roof of the next day.

5.2: Waterproofing Of Slab Or Balcony
Clean all the surface area of the balcony and using the chisel to remove the extra mortar on the slab and then apply a thick cement slurry over the top surface of the balcony.

You are advised to apply the SINOMACO SC2000 cementitious coating or SPU1000 polyurethane liquid membrane as waterproofing layers in 2-3 time brush.

Applying a cement sand mortar of ratio 1:4 over the finishing coat and waterproofing compound as per design. This waterproofing compound is cured for a minimum of 7 days.

5.3: Waterproofing Of Over Head Tank:
Clean the base surface and remove the extra concrete in the tank and clear its corners from concrete around the chamber.
Then apply the SINOMACO SC2000 cementitious coating or SPU1000 polyurethane liquid membrane as waterproofing layers in 2-3 time brush or more to penetrate cracks and holes of the bottom of the slab surface.
It is very simple to waterproof a water tank. Check out the inlet and outlet of pipes. If the pipes are not in rigid shape so grout is used to make the rigidity. Check the levels of pipes before the grouting.
Adding waterproofing compound on cement sand mortar of ratio 1:4 on the corners of the tank and bottom of the slab surface. Minimum 15 to 20mm thick plaster is provided over the surface. The top slab surface should not require waterproofing. This waterproofing compound is cured for a minimum of 7 days.


Post time: Dec-03-2020